Trouble-clearing procedures
NTPOOSYNC
....................................................................................................................................................................................................................................
While NTP is enabled, if all provisioned servers become not reachable or fail to meet
minimum server standards, a NTPOOSYNC condition shall be raised. This alarm shall
clear when the NTP protocol is disabled or NTP server time synchronization is
reestablished.
Once the NE is power cycled, it takes approximately 20-30 minutes to initialize.
Thereafter, time synchronization will be completed, with a maximum delay time of 2-3
minutes.
Note: When configuring NTP servers on an NE network, the provisioned NTP server
IP addresses should be that of external NTP servers, not the IP addresses of GNEs.
Provision appropriate DCNs such that the external NTP servers are reachable from all
NEs within the network. This is especially important in the event of an EC cold reboot
or EC replacement. Do not use an NE as an NTP server by remote NEs.
Severity
Service affecting?
Applicability
Corrective Action
At the end of each step wait to see if the fault clears. If not, continue with the next step.
...................................................................................................................................................................................................
Verify provisioned servers are valid and reachable. If not, consult network engineering for
1
correct server addresses.
...................................................................................................................................................................................................
2
Perform a warm reset on the Equipment Controller that is raising the NTPOOSYNC
condition.
CLI
WEBUI
...................................................................................................................................................................................................
Perform a cold reset on the Equipment Controller that is raising the NTPOOSYNC
3
condition.
CLI
WEBUI
....................................................................................................................................................................................................................................
2-206
NA
No
SYSTEM
card type shelf slot
config card
Select the card, click the
card type shelf slot
config card
Select the card, click the
NTPOOSYNC (Network Time Protocol is enabled, but no NTP
reset warm
Reboot
tab, select
Warm Reboot
reset cold
Reboot
tab, select
Cold Reboot
8DG60888CAAA Release 3.6.0 and 3.6.1
server is reachable)
>
Submit
.
>
Submit
.
1830 PSS-36/PSS–32/PSS-16/PSS-4
Issue 1 June 2011

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

1830 pss-321830 pss-361830 pss-4

Table of Contents