Trouble-clearing procedures
OPR
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
Retrieve the optical power levels at the receive port of the OT or SVAC card where the
2
alarm is raised.
CLI
WEBUI
...................................................................................................................................................................................................
3
If...
the power levels are within the acceptable
limits,
the power levels are not within acceptable
limits,
...................................................................................................................................................................................................
4
Thoroughly clean the fiber jumper connected to the receive port of the OT or SVAC card
raising the alarm.
...................................................................................................................................................................................................
Thoroughly clean the fiber bulkhead connector of the receive port of the OT or SVAC
5
card raising the alarm.
...................................................................................................................................................................................................
6
Perform a warm reset of the card.
CLI
WEBUI
...................................................................................................................................................................................................
Perform a cold reset of the card.
7
CLI
WEBUI
...................................................................................................................................................................................................
Reseat the card. Refer to
8
....................................................................................................................................................................................................................................
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
Issue 1 June 2011
show interface <shelf slot port>
From the Equipment Tree, select the card, and select the desired port.
card_type shelf slot
config card
Select the card, click the
card_type shelf slot
config card
Select the card, click the
"Reseating a Card" (p.
OPR (Channel Optical Power Out of Range)
Then...
the problem may be with the card itself.
Proceed to
Step
6.
continue with
Step
reset warm
Reboot
tab, select
Warm Reboot
reset cold
Reboot
tab, select
Cold Reboot
3-19).
4.
>
Submit
.
>
Submit
.
2-229