Trouble-clearing procedures
APSCM
....................................................................................................................................................................................................................................
• there is a service mismatch.
• the far end is currently performing a software upgrade.
Severity
Service affecting?
Applicability
Corrective Action
Replacing and reconnecting optical patch cords may be service affecting. It is
recommended to replace and reconnect optical patch cords during a maintenance
window.
At the end of each step wait to see if the fault clears. If not, continue with the next step.
...................................................................................................................................................................................................
Observe the protection information presented in the APSCM condition. Note the
1
protection group information and the cards involved.
...................................................................................................................................................................................................
Login to the near end NE and perform the procedure
2
Service" (p. 3-10)
reporting the APSCM alarm.
...................................................................................................................................................................................................
3
Open a new window and log into the far-end NE identified in
...................................................................................................................................................................................................
Enter the following commands on both the near-end and far-end NEs to confirm that the
4
protection group is configured as desired.
CLI
1. Ensure that the near-end and far-end interfaces are in the same protection group.
2. Check the direction of the protection group.
3. Validate that the protection group has a valid working and protection path.
....................................................................................................................................................................................................................................
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
Issue 1 June 2011
Not alarmed
No
11STAR1, 11STMM10, 11STGE12
NOTICE
Service-disruption hazard
to determine the NE and card that link directly to the (near-end) card
config aps group <group_id> detail
APSCM (APS Channel Mismatch)
"Determining the Far End of a
Step
2.
2-39