Trouble-clearing procedures
REPLUNITMISSMOD
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
Remove the pluggable module from the port on the card it is inserted in. Examine the
3
connector on the SFP and the receptacle connector on the card where the SFP plugs into
for any damage. If no damage is seen, reinsert the pluggable module into its port.
...................................................................................................................................................................................................
Remove and replace the pluggable module with another unit of the same type, being
4
careful with the connected fiber jumpers. Refer to
...................................................................................................................................................................................................
5
Perform a cold reset of the card on the card where the pluggable module failure is raised.
CLI
WEBUI
...................................................................................................................................................................................................
Reseat the card. Refer to
6
...................................................................................................................................................................................................
Replace the card. Refer to
7
E
N D
O F
...................................................................................................................................................................................................
RFIEGR
RFIEGR (Remote Client Remote Fault)
The OT port has detected a Remote Fault Identifier (RFI) ordered set on the 10GbE LAN
service transported over the OTUk in the transmit direction.
This may be caused if the remote client equipment is generating RFI ordered sets.
Severity
Service affecting?
Applicability
This procedure details the corrective action for clearing RFIEGR declared on an OT port.
...................................................................................................................................................................................................
1
Locate far end OT.
....................................................................................................................................................................................................................................
2-284
config card
Select the card, click the
"Reseating a Card" (p.
"Replacing System Components" (p.
S T E P S
NA
No
11QPA4, 11STAR1, 43STX4
"Replacing an SFP Module" (p.
card_type shelf slot
reset cold
Reboot
tab, select
3-19).
REPLUNTMISS (Pluggable Module Missing)
Cold Reboot
>
Submit
3-20).
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
Issue 1 June 2011
3-27).
.