Trouble-clearing procedures
OCHTRAILUNKNOWN
....................................................................................................................................................................................................................................
If...
there is no match,
...................................................................................................................................................................................................
4
Ensure that there is CN/OSPF connectivity at the head end NE. Log into the head end NE.
Check for alarms on any ALPHG links. Resolve any outstanding alarms on the head-end
NE CN links.
...................................................................................................................................................................................................
5
Ensure that the OCh trail's head NE cross-connect has been created. Log into the head end
NE for that connection. List the cross-connects that currently exist on this head-end NE:
CLI
WEBUI
...................................................................................................................................................................................................
6
Search the list for the OCh trail in question.
If...
a match is not found,
a match is found,
...................................................................................................................................................................................................
Ensure that there is CN/OSPF connectivity at the NE raising the condition. Log into the
7
NE raising the condition. Check for alarms on any ALPHG links. Resolve any
outstanding alarms on the NE CN links.
E
N D
O F
...................................................................................................................................................................................................
OCHUNKNOWN
OCHUNKNOWN (Channel Unexpected)
Wavelength Tracker has detected an instance of a channel that was not provisioned at an
input port. The provisioning of a service is not yet complete, or there has been a
misfibering. This alarm may be the result of misdirected traffic or it may be a transient
during service creation.
....................................................................................................................................................................................................................................
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
Issue 1 June 2011
show xc brief
Select
Connections
S T E P S
OCHTRAILUNKNOWN (Unknown OCH Trail for x-connect)
Then...
continue with
>
.
Cross-Connects
Then...
create the add connection.
continue with
Step
4.
Step
7.
2-223