Trouble-clearing procedures
VOLTAGEHIGH
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
Perform a warm reset on the Equipment Controller that is raising the PWR condition.
2
CLI
WEBUI
...................................................................................................................................................................................................
Perform a cold reset on the Equipment Controller that is raising the PWR condition.
3
CLI
WEBUI
...................................................................................................................................................................................................
4
Reseat the Equipment Controller that is raising the PWR condition.
...................................................................................................................................................................................................
Replace the Equipment Controller that is raising the PWR condition. Follow the return
5
and repair process to return the card to an authorized repair center for replacement.
E
N D
O F
...................................................................................................................................................................................................
VOLTAGELOW
VOLTAGELOW [Low input voltage defect]
Either the voltage level of the external DC supply is low or the breaker switch has been
turned off. This alarm is raised if there is no voltage going to the breaker feed or the
voltage is below the threshold. This could be due to the breaker being shut off, or due to a
problem with the power feed to the breaker card.
Severity
Service affecting?
....................................................................................................................................................................................................................................
2-350
config card
Select the card, click the
config card
Select the card, click the
S T E P S
Critical
No
card type shelf slot
reset warm
tab, select
Reboot
card type shelf slot
reset cold
Reboot
tab, select
VOLTAGEHIGH [High input voltage defect]
>
Warm Reboot
Submit
Cold Reboot
>
Submit