Command
(Instruction
Parameter
Type
Code and
or Response
Qualifier)
Remote
SPA=
4 bytes
Address
Set Serial
SPB=
3 bytes
Format
SNMP Read
SRC=
16 bytes,
Community
characters,
no spaces
SNMP
SSC=
255 bytes,
System
characters
Contact
Serial-based Remote Product Management
Arguments
for
Description of Arguments
Command
(Note that all arguments are ASCII
numeric codes between 48 and 57)
to Query
Command or Query.
Set Physical Address-between 0001 to 9999.
Resolution 0001
Example:
<1/SPA=0412'cr'
>0001/SPA='cr''lf'
Default Value: 0001
Command or Query.
Set the Serial Data Bits, Parity, and Stop Bits.
Format: XYZ with valid combinations of 8N1, 7E2, and 7O2.
Where:
X = Serial Data Bits (7 or 8)
Y = Parity (N = None, E = Even, O = Odd)
Z = Stop Bits (1 or 2)
Example:
<1/SPB=7E2'cr'
>0001/SPB='cr''lf'
Default Value: 8N1
Command or Query.
SNMP read community string. Empty string is not allowed
Example:
<1/SRC=public
Command or Query.
SNMP System Contact string.
Example:
<1/SSC=Joe Net Admin
If not configured, it returns empty string: <1/SSC=
TRP1000-4450 Troposcatter C-Band Outdoor Amplifier
Response to
Command
(Target to
Controller)
SPA=
SPB=
SPB?
SRC =
SRC!
SSC =
SSC!
5–31
Revision 0
Query
Response
(Instruction
to Query
Code and
(Target to
Qualifier)
Controller)
SPA?
SPA=xxxx
(Same
format as
command
arguments)
SPB?
SPB=XYZ
(Same
format as
command
arguments)
SRC?
SRC =x
(See
description
of
arguments)
SSC?
SSC =x
[1..128]
(See
description
of
arguments)