Comtech EF Data TRP1000-OD Installation And Operation Manual page 89

Troposcatter c-band outdoor amplifier
Table of Contents

Advertisement

Command
(Instruction
Parameter
Type
Code and
or Response
Qualifier)
Retrieve
Alarm Status
(Continued)
Serial-based Remote Product Management
Arguments
for
Description of Arguments
Command
(Note that all arguments are ASCII
numeric codes between 48 and 57)
to Query
(Continued)
The Alarm status of the unit,
Where:
OK = no fault condition,
FT = faulted,
AL = alarm,
MS = masked.
System Alarm Status where:
SYS-INPWR = System Input Power
SYS-FWPWR = System Forward Power
SYS-RVPWR = System Reverse Power
SYS-OTEMP= Outside Temperature
SYS-INTEMP= Internal Temperatures Module 1 Alarm
Status where:
RF1-PS24V = 24 Volt Power Supply
RF1-PS13V = 13.5 Volt Power Supply
RF1-P5V8T = +5.8 Volt Power Supply
RF1-N5V8T = -5.8 Volt Power Supply
RF1-ATEMP = Heat Sink Temperature
RF1-ETEMP = Exhaust Temperature
RF1-RFAN1 = Module Fan 1 Speed
RF1-RFAN2 = Module Fan 2 Speed
RF1-RFAN3 = Module Fan 3 Speed
Note: ETEMP-OTEMP < 30C is Okay
Power Supply Alarm Status where:
PS1-PS40V = 40V PS
PS1-PS10V = 10V PS
PS1-PS40I = 40V PS Current
PS1-PS24I = 24 Volt PS current
PS1-PS10I = 10 Volt PS current
PS1-P5V8T = +5.8 Volt Power Supply
PS1-PFAN1 = Module Fan 1 Speed
PS1-PFAN2 = Module Fan 2 Speed
TRP1000-4450 Troposcatter C-Band Outdoor Amplifier
Response to
Command
(Target to
Controller)
5–21
Revision 0
Query
Response
(Instruction
to Query
Code and
(Target to
Qualifier)
Controller)
MN-TRP1000-OD

Advertisement

Table of Contents
loading

Table of Contents