Comtech EF Data TRP1000-OD Installation And Operation Manual page 100

Troposcatter c-band outdoor amplifier
Table of Contents

Advertisement

Command
(Instruction
Parameter
Type
Code and
or Response
Qualifier)
Set Statistics
SSI=
2 bytes
Interval
SNMP
SSL=
255 bytes,
System
characters
Location
SNMP
SCN=
16 bytes,
Unit Name
characters
SNMP Trap
STA=
15 bytes,
Destination
Numerical
IP Address 1
Serial-based Remote Product Management
Arguments
for
Description of Arguments
Command
(Note that all arguments are ASCII
numeric codes between 48 and 57)
to Query
Command or Query.
Sets the interval at which statistics are logged. Minimum
resolution is 1 minute, maximum is 99 minutes.
Example:
<1/SSI=90'cr'
>0001/SSI='cr''lf'
Default Value: 90
Command or Query.
SNMP System Location string
Example:
<1/SSL=Upstairs back right
If not configured it returns empty string. <1/SSL=
Command or Query.
SNMP System Name string
Example:
<1/SCN=Remote1
If not configured it returns empty string. <1/SCN=
Command or Query.
Used to set the IP address of the first SNMP Trap destination
IP Address 1
Where traps will be sent in the form:
xxx.xxx.xxx.xxx is the IP addresss
Example:
<1/STA=010.006.030.001
When not configured, returns >0001/STA=0.0.0.0
TRP1000-4450 Troposcatter C-Band Outdoor Amplifier
Response to
Command
(Target to
Controller)
SSI=
SSI?
SSL =
SSL!
SCN =
SCN!
STA =
STA!
5–32
Revision 0
Query
Response
(Instruction
to Query
Code and
(Target to
Qualifier)
Controller)
SSI?
SSI=xx
(Same
format as
command
arguments)
SSL?
SSL =x
[1..128]
(See
description
of
arguments)
SCN?
SCN =x
[1..128]
(See
description
of
arguments)
STA?
STA=xxx.xx
x.xxx.xxx
(See
description
of
arguments)
MN-TRP1000-OD