Comtech EF Data TRP1000-OD Installation And Operation Manual page 79

Troposcatter c-band outdoor amplifier
Table of Contents

Advertisement

Command
(Instruction
Parameter
Type
Code and
or Response
Qualifier)
Attenuation
ATT=
5 bytes
Auxilliary
AUX=
1 byte
Mute
Clear All
CAA=
None
Stored
Alarms
Clear All
CAE=
None
Stored
Events
Serial-based Remote Product Management
Arguments
for
Description of Arguments
Command
(Note that all arguments are ASCII
numeric codes between 48 and 57)
to Query
Command or Query.
Set the RF attenuation level from 0 to 10dB in 0.25dB steps.
Example:
<1/ATT=10.00'cr'
>0001/ATT='cr''lf'
Default Value: 10.00
Default ATT Step: 0.25 dB
Command or Query.
Enable or disable the auxiliary mute hardware control.
Where:
1 = auxiliary mute enabled
0 = auxiliary mute disabled
Example:
<1/AUX=1'cr'
>0001/AUX='cr''lf'
Default Value: 0
Command only.
Instructs the unit to clear all Stored Alarms. This command
takes no arguments.
Example:
<1/CAA='cr'
>0001/CAA='cr''lf'
Command only.
Clear all Stored Events. This command takes no arguments.
Example:
<1/CAE='cr'
>0001/CAE='cr''lf'
TRP1000-4450 Troposcatter C-Band Outdoor Amplifier
Response to
Command
(Target to
Controller)
ATT=
ATT?
ATT*
AUX=
AUX?
AUX*
CAA=
CAA*
CAE=
CAE*
5–11
Revision 0
Query
Response
(Instruction
to Query
Code and
(Target to
Qualifier)
Controller)
ATT?
ATT=xx.xx
(Same
format as
command
arguments)
AUX?
N/A
N/A
N/A
N/A
MN-TRP1000-OD