Comtech EF Data TRP1000-OD Installation And Operation Manual page 81

Troposcatter c-band outdoor amplifier
Table of Contents

Advertisement

Command
(Instruction
Parameter
Type
Code and
or Response
Qualifier)
Enable
ESA=
1 byte
Statistics
Averaging
Retrieve
N/A
Firmware
Number
Serial-based Remote Product Management
Arguments
for
Description of Arguments
Command
(Note that all arguments are ASCII
numeric codes between 48 and 57)
to Query
Command or Query.
Enable or disable statistics averaging. When statistics
averaging is enabled all new entries in the statistics log are
comprised of averaged measurements.
Where:
0 = Disable
1 = Enable
Example:
<0001/ESA=1'cr'
>0001/ESA=1'cr''lf'
Default Value: 0
Query only.
Returns the firmware type(s) loaded into the unit. The firmware
information is returned in the following format:
FW-AAAAAAA B.B.BB DD/MM/YY
Where:
FW-AAAAAAA = the firmware part number
B.B.BB = the version number
DD/MM/YY = Day/Month/Year firmware released
Example:
<1/FRW?'cr'
>0001/FRW=
Boot:
FW-0000082 0.0.1a 04/09/08
Bulk1:
FW-0000078 0.0.1a 04/09/08
FW-0000080 0.0.1a 04/09/08
FW-0000081 0.0.1a 04/09/08
Bulk2:
FW-0000078 0.0.1a 04/09/08
FW-0000080 0.0.1a 04/09/08
FW-0000081 0.0.1a 04/09/08
TRP1000-4450 Troposcatter C-Band Outdoor Amplifier
Response to
Command
(Target to
Controller)
ESA=
ESA?
ESA*
FRW=
5–13
Revision 0
Query
Response
(Instruction
to Query
Code and
(Target to
Qualifier)
Controller)
ESA?
FRW?
FRW={CR}B
oot:{CR}abc
{CR}Bulki:{C
R}abc{CR}a
bc
(See
description
for details of
arguments)
MN-TRP1000-OD

Advertisement

Table of Contents