Command
(Instruction
Parameter
Type
Code and
or Response
Qualifier)
Unit Alarm
MSK=
9 bytes
Mask
Serial-based Remote Product Management
Arguments
for
Description of Arguments
Command
(Note that all arguments are ASCII
numeric codes between 48 and 57)
to Query
Command or Query.
Alarm mask conditions. If the mask value for a certain
parameter is set to fault, then a fault condition will be
registered if specified hardware conditions are not met. If the
mask value is set to alarm, then a fault condition will only
appear to be an alarm that will not set the summary fault
relay. If the mask value is set to masked, then the fault will
never be reported to the user.
Form of: abcdefghij
Where:
0 = Fault, 1 = Alarm, 2 = Masked
a = Module1 Fan1 Speed
b = Module1 Fan2 Speed
c = Module1 Fan3 Speed
d = Sealed PS Fan1 Speed
e = Sealed PS Fan2 Speed
f = Sealed PS Fan3 Speed
g = High Input Power
h = High Reverse Power
i = Low Forward Power
j=High Forward Power
Example:
<0001/MSK=2222222222'cr'
>0001/MSK='cr''lf'
Default Value: 2222222222
TRP1000-4450 Troposcatter C-Band Outdoor Amplifier
Response to
Command
(Target to
Controller)
MSK=
MSK?
MSK*
5–19
Revision 0
Query
Response
(Instruction
to Query
Code and
(Target to
Qualifier)
Controller)
MSK=abcde
MSK?
fghi
(See
description
for details of
arguments)