Comtech EF Data TRP1000-OD Installation And Operation Manual page 82

Troposcatter c-band outdoor amplifier
Table of Contents

Advertisement

Command
(Instruction
Parameter
Type
Code and
or Response
Qualifier)
Hardware ID
N/A
1 byte
High Power
HPT=
5 bytes
Threshold
Initialize
IEP=
None
Events
Pointer
Serial-based Remote Product Management
Arguments
for
Description of Arguments
Command
(Note that all arguments are ASCII
numeric codes between 48 and 57)
to Query
Query only:
Returns the value of the Hardware ID byte.
Example:
<0001/HID?'cr'
>0001/HID=0'cr''lf'
Command or Query.
This command allows the user to set the threshold for the
high forward power alarm/fault. If the forward power rises
above the specified value, the alarm/fault will be indicated.
HPT=xx.xx,
Where:
xx.xx = a real number between 48.00 and 64.00 dBm.
Example:
<1/HPT=63.00'cr'
>0001/HPT='cr''lf'
Command only.
Resets internal pointer to allow RNE? Queries to start at the
beginning of the stored events log.
Example:
<1/IEP='cr'
>0001/IEP='cr''lf'
TRP1000-4450 Troposcatter C-Band Outdoor Amplifier
Response to
Command
(Target to
Controller)
HID=
HPT=
HPT?
HPT*
IEP=
IEP?
IEP*
5–14
Revision 0
Query
Response
(Instruction
to Query
Code and
(Target to
Qualifier)
Controller)
HID?
HID=x
High Power
HPT?
Threshold
N/A
N/A
MN-TRP1000-OD

Advertisement

Table of Contents
loading

Table of Contents