Comtech EF Data TRP1000-OD Installation And Operation Manual page 95

Troposcatter c-band outdoor amplifier
Table of Contents

Advertisement

Command
(Instruction
Parameter
Type
Code and
or Response
Qualifier)
Retrieve
N/A
xx bytes
Next 5
unread
stored
Events
Serial-based Remote Product Management
Arguments
for
Description of Arguments
Command
(Note that all arguments are ASCII
numeric codes between 48 and 57)
to Query
Query only.
Unit returns the oldest 5 Stored Events which have not yet
been read over the remote control.
Reply format: {CR}Sub-body{CR}Sub-body{CR}Sub-
body{CR} Sub-body{CR}Sub-body,
Where:
Sub-body= ddmmyyhhmmssABCC:
A being the fault type
Where:
1=System
2=RF Module 1
3=PS Module 1
B being the fault/clear indicator.
F=Fault
C=Clear
I=Info
CC is Fault or Alarm description:
Example:
<1/RNE?
>1/RNE=
06-22-15 11:57:50 RF1 FLT +13.5V PS
06-22-15 11:57:50 RF1 ALM Heat Sink Temp
06-22-15 11:57:50 RF1 ALM Exhaust Temp
06-22-15 11:57:51 RF1 FLT +24V PS
TRP1000-4450 Troposcatter C-Band Outdoor Amplifier
Response to
Command
(Target to
Controller)
RNE=
5–27
Revision 0
Query
Response
(Instruction
to Query
Code and
(Target to
Qualifier)
Controller)
RNE={CR}A
RNE?
BCCddmmy
yhhmmss{C
R}ABCCdd
mmyyhhmm
ss{CR}ABC
Cddmmyyhh
mmss{CR}A
BCCddmmy
yhhmmss{C
R}ABCCdd
mmyyhhm
mss
(See
description
for details of
arguments)
MN-TRP1000-OD

Advertisement

Table of Contents
loading

Table of Contents