Comtech EF Data TRP1000-OD Installation And Operation Manual page 96

Troposcatter c-band outdoor amplifier
Table of Contents

Advertisement

Command
(Instruction
Parameter
Type
Code and
or Response
Qualifier)
Read Next 5
N/A
436 bytes,
Statistics
alpha-
numeric
Reverse
RPT=
5 bytes
Power
Threshold
Serial-based Remote Product Management
Arguments
for
Description of Arguments
Command
(Note that all arguments are ASCII
numeric codes between 48 and 57)
to Query
Query only.
Returns the next five unread statistics stored in the statistics
log.
Returns 5 lines with the following format:
mm-dd-
yy;HH:MM:SS;a;b;c;dd.dd;ee.ee;ff.ff;gg.gg;hh.hh;ii.ii;jj.jj;kk.kk
;ll.ll;mm.mm;nn.nn;
Where:
mm-dd-yy = entry date
HH:MM:SS = entry time
a = amplifier enable state
b = mute enable state
c = summary fault state
dd.dd = RF attenuation
ee.ee = input power monitor
ff.ff = forward power monitor
gg.gg = reverse power monitor
hh.hh = outside temp
ii.ii = system 40V rail
jj.jj = RF 10V rail
kk.kk = RF 40I current
ll.ll = RF 10I current
mm.mm = heatsink temp
nn.nn = exhaust temp
Command or Query.
Sets the power threshold used to generate a reverse power
threshold alarm or fault condition (depending on the MSK
state) Format xx.xx,
Where:
xx.xx = the reverse power threshold level in dBm
TRP1000-4450 Troposcatter C-Band Outdoor Amplifier
Response to
Command
(Target to
Controller)
RNS=
RPT=
5–28
Revision 0
Query
Response
(Instruction
to Query
Code and
(Target to
Qualifier)
Controller)
RNS?
RNS=x....x
(See
description
for details of
arguments)
RPT?
RPT=xx.xx
MN-TRP1000-OD

Advertisement

Table of Contents
loading