Comtech EF Data TRP1000-OD Installation And Operation Manual page 59

Troposcatter c-band outdoor amplifier
Table of Contents

Advertisement

Amplifier
Amplifier – Use the drop-down list to select the amplifier as either On or Off.
Mute – Use the drop-down list to select the Mute as either Enabled or Disabled.
Aux Mute – Use the drop-down list to select the Mute as either Enabled or Disabled.
Enabled allow the Mute signal on the communication connector to control the mute function.
Atenuation (dB) – Enter a valid attenuation level (00.00 to 20.00 dB) in 0.25 dB steps.
Fault Recovery – Use the drop-down list to select Fault Recovery as either Automatic or
Manual.
Click [Save Changes] to save.
Threshold Power Settings
RF Input Threshold (dBm)
RF Output Min Threshold (dBm)
RF Output Max Threshold (dBm)
RF Reverse Threshold (dBm)
Use the field to set the threshold value, in dBm, for each parameter. When the forward power
monitor is set to Alarm or Fault instead of the factory default of Mask, and the forward power
drops below the specified value, the alarm/fault is indicated.
Setting this parameter to the default value of 00.00 effectively disables the threshold.
Click [Save Changes] to save.
Ethernet-based Remote Product Management
TRP1000-4450 Troposcatter C-Band Outdoor Amplifier
4–15
Revision 0
MN-TRP1000-OD