2.2.2

RF Output Connector 'J2 | RF OUT'

For safety reasons, never look directly into the waveguide output. Also,
never apply power to the unit without an appropriate
termination/connection to the waveguide flange.
2.2.3
AC Power Main Connector 'J3 | AC IN'
Pin #
A
B
C
System Connections, Installation and Startup
The 'J2 | RF OUT' connector is a CPR187G waveguide flange interface. Be
careful not to allow any unwanted material to enter the waveguide output while
the interface is open. The opening is covered with a protective material during
shipment. Assuming the mating flange is also a type CPR187G interface, use
the supplied gasket to ensure a watertight connection, and make sure the
screws used to secure the mating flange do not bottom out.
The AC prime power input requirements for the TRP1000-4450 are as follows:
200-250 VAC
47 to 63 Hz
The power supply is power factor corrected. See Sect. 1.5 Summary of
Specifications for the total power required from the prime power supply.
Mating Connector: CEFD PN CN/MS-STPG03F07 (Glenair ITS3106F20-
19SF7).
Table 2-1. Connector 'J3 | AC IN' Pin Assignments
TRP1000-4450 Troposcatter C-Band Outdoor Amplifier
Description
GND
NEUTRAL (L2)
LINE (L1)
2–3