2.2.2
RF Output Connector 'J2 | RF OUT'
For safety reasons, never look directly into the waveguide output. Also,
never apply power to the unit without an appropriate
termination/connection to the waveguide flange.
2.2.3
AC Power Main Connector 'J3 | AC IN'
Pin #
A
B
C
System Connections, Installation and Startup
The 'J2 | RF OUT' connector is a CPR187G waveguide flange interface. Be
careful not to allow any unwanted material to enter the waveguide output while
the interface is open. The opening is covered with a protective material during
shipment. Assuming the mating flange is also a type CPR187G interface, use
the supplied gasket to ensure a watertight connection, and make sure the
screws used to secure the mating flange do not bottom out.
The AC prime power input requirements for the TRP1000-4450 are as follows:
•
200-250 VAC
•
47 to 63 Hz
The power supply is power factor corrected. See Sect. 1.5 Summary of
Specifications for the total power required from the prime power supply.
Mating Connector: CEFD PN CN/MS-STPG03F07 (Glenair ITS3106F20-
19SF7).
Table 2-1. Connector 'J3 | AC IN' Pin Assignments
TRP1000-4450 Troposcatter C-Band Outdoor Amplifier
Description
GND
NEUTRAL (L2)
LINE (L1)
2–3
Revision 0