Comtech EF Data TRP1000-OD Installation And Operation Manual page 97

Troposcatter c-band outdoor amplifier
Table of Contents

Advertisement

Command
(Instruction
Parameter
Type
Code and
or Response
Qualifier)
Retrieve
N/A
23 bytes,
Utility Status
alpha-
numeric
Summary
N/A
1 byte
Alarm Status
Remote Baud
SBR=
5 bytes
Rate
Serial-based Remote Product Management
Arguments
for
Description of Arguments
Command
(Note that all arguments are ASCII
numeric codes between 48 and 57)
to Query
Query only.
Used to Query the utility status of the unit.
Where:
ADR = the serial address
BDR = the serial baud rate
FMT = the serial format
VFD = the VFD brightness setting
Query only.
Indicates if there are any active alarm conditions.
SAS=x,
Where:
0 = no active alarms
1 = at least one active alarm
Example:
<1/SAS?
>0001/SAS=0'cr''lf'
Command or Query.
Set remote baud rate as follows:
02400 = 2400 baud
04800 = 4800 baud
09600 = 9600 baud
19200 = 19200 baud
38400 = 38400 baud
Examples:
<0001/SBR=9600'cr'
>0001/SBR='cr''lf'
<0001/SBR?'cr'
>0001/SBR=09600'cr''lf'
Note: When changing baud rates remotely the response to
the command will be returned using the same baud
rate as that used to send the command.
Default Value: 09600
TRP1000-4450 Troposcatter C-Band Outdoor Amplifier
Response to
Command
(Target to
Controller)
RUS=
SAS=
SBR=
SBR?
SBR*
5–29
Revision 0
Query
Response
(Instruction
to Query
Code and
(Target to
Qualifier)
Controller)
RUS?
RUS=x....x
(See
description
for details of
arguments)
SAS?
SAS=x
(See
description
for details of
arguments)
SBR?
SBR=xxxxx
(Same
format as
command
arguments)
MN-TRP1000-OD