4. Use the TRP1000-4450 Web Server Interface to select the boot image. To select the
desired boot Image, open the TRP1000-4450 Web Server Interface 'Config | Utility' page.
Use the Next Reboot Image drop-down list in the Current Active Firmware Image # section
to select 1 or 2, and then click [Submit].
5. Reboot the TRP1000-4450.
a. Disconnect the power source from the TRP1000-4450.
b. Re-energize the TRP1000-4450. The unit will reboot using the updated firmware image.
6. To update the other firmware image, repeat steps 1 through 5.
The TRP1000-4450 is now operating with its latest firmware. The Ethernet-
based firmware update process is now complete.