Comtech EF Data TRP1000-OD Installation And Operation Manual page 83

Troposcatter c-band outdoor amplifier
Table of Contents

Advertisement

Command
(Instruction
Parameter
Type
Code and
or Response
Qualifier)
Software
IMG=
1 byte
Image
IP Address
IPA=
18 bytes
Serial-based Remote Product Management
Arguments
for
Description of Arguments
Command
(Note that all arguments are ASCII
numeric codes between 48 and 57)
to Query
Command or Query.
Current Active software image,
Where:
1=Bulk Image # 1 currently active
2=Bulk Image # 2 currently active
Examples:
<1/IMG=1'cr' (instructs the unit to load firmware from image
#1 at the next reset / power up).
<1/IMG?'cr' (queries the image number that the firmware
loaded during bootup)
Note: If the user sends the IMG command, and then queries
the IMG value, the numbers may not be equal because
the command tells the firmware which image to boot
from at the next bootup, and the query reports the
image that the firmware booted from on the last bootup.
Command or Query.
Used to set the IP address and network prefix for the 10/100
BaseT Ethernet management port, in the format:
xxx.xxx.xxx.xxx.yy,
Where:
xxx.xxx.xxx.xxx is the IP address, and
yy is the network prefix (8-30)
Example:
<1/IPG=192.168.001.004.24'cr'
>0001/IPG='cr''lf'
Note: Changing the IP address through the Telnet interface
requires the user to power cycle the unit, and then
restart a new Telnet session with the new IP address.
The IP address typed into the Telnet client software
does not include the range parameter, so it would be:
192.168.1.4.
Default Value: 192.168.001.004.24
TRP1000-4450 Troposcatter C-Band Outdoor Amplifier
Response to
Command
(Target to
Controller)
IMG=
IMG?
IMG*
IMG#
IPA=
IPA?
IPA*
IPA#
5–15
Revision 0
Query
Response
(Instruction
to Query
Code and
(Target to
Qualifier)
Controller)
IMG?
IMG=x
(See
description
for details of
arguments)
IPA?
IPA=
xx.xxx.xxx.x
xx.yy
(See
description
of
arguments)
MN-TRP1000-OD

Advertisement

Table of Contents
loading

Table of Contents