Comtech EF Data TRP1000-OD Installation And Operation Manual page 102

Troposcatter c-band outdoor amplifier
Table of Contents

Advertisement

Command
(Instruction
Parameter
Type
Code and
or Response
Qualifier)
Temperature
N/A
7 bytes
Retrieve
N/A
2 bytes
Number of
unread
Stored
Alarms
Total Number
N/A
2 bytes
of Events
Serial-based Remote Product Management
Arguments
for
Description of Arguments
Command
(Note that all arguments are ASCII
numeric codes between 48 and 57)
to Query
Query only.
Returns the specified temperature.
Where:
0 = RF Module #1 Heatsink Temp
1 = RF Module #1 Inlet Temp
2 = RF Module #1 Exhaust Temp
Example:
<1/TMP?0'cr'
>0001/TMP=+052.27'cr''lf'
Query only.
Returns the number of stored events, which remain unread in
the alarm log.
Example reply:
<1/TNA? 'cr'
>0001/TNA=14'cr''lf'
Query only.
Returns the number of unread entries in the stored events
log.
Example:
<1/TNE? 'cr'
>0001/TNE=14'cr''lf'
TRP1000-4450 Troposcatter C-Band Outdoor Amplifier
Response to
Command
(Target to
Controller)
TMP=
TNA=
TNE=
5–34
Revision 0
Query
Response
(Instruction
to Query
Code and
(Target to
Qualifier)
Controller)
TMP?
TMP=x
(See
description
for details of
arguments)
TNA?
TNA=xx
(See
description
for details of
arguments)
TNE?
TNE=xx
(See
description
for details of
arguments)
MN-TRP1000-OD

Advertisement

Table of Contents
loading

Table of Contents