Advertisement

Command
(Instruction
Parameter
Type
Code and
or Response
Qualifier)
Serial-based Remote Product Management
Arguments
for
Description of Arguments
Command
(Note that all arguments are ASCII
numeric codes between 48 and 57)
to Query
PFAN2 = PS Fan #2 Speed in Percent
PFAN3 = PS Fan #3 Speed in Percent
PS40V = +40V Power Supply
PS40I = +40V Current
PS24I = +24V Power Supply
PS10V = +10V FET Voltage
PS10I = +10V FET Current
P5V8T = +5.8V Voltage
RF Module:
PS24V = +24V Fan Voltage
PS13V = +13.5V Voltage
RP5V8 = +5.8V Power Supply
RN5V8 = -5.8V Power Supply
RFAN1 = RF Fan #1 Speed in Percent
RFAN2 = RF Fan #2 Speed in Percent
RFAN3 = RF Fan #3 Speed in Percent
FWPWR = Module RF Forward Power in dBm
INPWR = System RF Input Power in dBm
RVPWR = System RF Reverse Power in dBm
ATEMP = Module Heatsink Temperature in deg C
OTEMP = Outdoor Temperature in deg C
ETEMP = Exhaust Temperature in deg C
Example:
<1/RMS?
>1/RMS=
>1/RMS=
PFAN1=094.0
PFAN2=095.0
PFAN3=096.0
PS40V=039.9
PS40I=067.0
PS24I=022.0
PS10V=010.1
TRP1000-4450 Troposcatter C-Band Outdoor Amplifier
Response to
Command
(Target to
Controller)
5–25
Revision 0
Query
Response
(Instruction
to Query
Code and
(Target to
Qualifier)
Controller)