Prime Power Requirements - Comtech EF Data TRP1000-OD Installation And Operation Manual

Troposcatter c-band outdoor amplifier
Table of Contents

Advertisement

Para.
1.5.1.19.2
4 kHz to 500 kHz
1.5.1.19.3
Above 500 kHz
1.5.1.20
Phase Noise
1.5.1.21
Noise & Spurious
1.5.1.22
Intermodulation Products for two equal
carriers anywhere in the Frequency Range
spaced 3 MHz apart with each carrier set to
the RF output power shown in paragraphs
1.5.1.22.1 to 1.5.1.22.2.
1.5.1.22.1
Each carrier set 6 dB below rated power
1.5.1.22.2
Each carrier set 9 dB below rated power
1.5.1.23
Spectral re-growth @ QPSK +/- 1 to 1.5
Symbol Rate offset
1.5.1.24
RF Output Power Monitor
Front Panel Marking:
1.5.2

Prime Power Requirements

Para.
1.5.2.1
Type
1.5.2.2
AC Voltage
1.5.2.3
Frequency
1.5.2.4
Power Consumption
1.5.2.5
Inrush Current
1.5.2.7
Ground Leakage Current
1.5.2.8
Power Interruption
1.5.2.9
EMC Conducted and Radiated
Introduction
TRP1000-4450 Troposcatter C-Band Outdoor Amplifier
Description
Coupling relative to RF Output:
Front panel Connector:
Table 1-2. Prime Power Requirements
Description
1–9
Specification
-20 (1.15 + log f), where f is in kHz
-77 dBc maximum
(IESS 308/309) -10dB
-70 dBc
The sum of the fundamental and each harmonic
component of the alternating (AC) line frequency
shall not exceed -40 dBc.
3
order IM products measured relative to either
rd
desired carrier at the RF output
-17 dBc
-25 dBc
-25 dBc minimum at any power up to 1 dB below
rated output power
50 dB, nominal
Type-N, Female
"OUTPUT SAMPLE"
Specification
Single phase, Three -wire
200-250 VAC
47 to 63 Hz
4500 VA maximum @ 1.0 kW output
144A peak
2 mA AC maximum
20 msec min without performance degradation
EN55022-Level A
FCC Part 15 Class A
Revision 0
MN-TRP1000-OD

Advertisement

Table of Contents
loading

Table of Contents