Cabling

Avaya P330 modules include the following types of ports (according to the speed
and standard they support): 10Base-T, 100Base-TX, 100Base-FX, 1000Base-SX and
1000Base-LX.
Note: To interconnect Avaya P330 switches with twisted pairs, crossed cables are
required.
The maximum UTP cable length connected to a 10/100 Mbps port operating as
10Base-T, is 100 m (328 ft.).
A UTP Category 5 cable must be connected to any 100Base-TX port, via an RJ45
connector. The maximum UTP cable length connected to a 10/100 Mbps port
operating as 100Base-TX, is 100 m (328 ft.).
A fiberoptic cable must be connected to any 100Base-FX port, via a pair of SC
connectors. The maximum fiber cable length connected to a 100Base-FX port is
412 m (1,352 ft) when operating in half duplex, and 2 km (6,562 ft) when
operating in full duplex.
Appropriate cables are available from your local supplier.
Table 4.3
Gigabit Interface
1000BASE-SX
1000BASE-SX
1000BASE-SX
1000BASE-SX
1000BASE-LX
1000BASE-LX
1000BASE-LX
1000BASE-SLX
*1000BASE-LX over Multimode fiber requires a special Patch cord cable which you
can obtain from your local cable supplier.
Avaya P333T User's Guide
Gigabit Ethernet Cabling
Fiber Type
MM
MM
MM
MM
MM
MM
SM
SM
Chapter 4
Diameter
Modal
(µm)
Bandwidth
62.5
160
62.5
200
50
400
50
500
62.5
500
50
500
9
NA
9
NA
Installation and Setup
Maximum
Distance (m)
220
275
500
550
550
550
5,000
10,000
27