s
DASHBOARD AND CONSOLE
05UOUX·161
o
====
,=Y
cS)==f)Q
TEMPERATURE BLEND
i\..
,""
,J
"""
""'
WIRE
05UOSX·106
S-52
REC-FRESH wire
1. Set the selector lever to FRESH position.
2. Connect and clamp the wire with the shutter lever on the
blower unit at its closest point.
Caution
• After installation, move the REC-FRESH lever to be
sure the wire is securely attached, and that it moves
the full stroke from REC to FRESH.
Temperature blend wire
1. Set the temperature blend lever to MAX-HOT position.
2. Connect and clamp the wire with the shutter lever on the
heater unit all the way to the right.
Caution
• After installation, move the temperature blend le-
ver to be sure the wire is securely attached, and that
it moves the full stroke from HOT to COLD.