Platform Components
2-3 Platform Ov erload System, S-60, S-65, S- 60 TRAX and S-65 TR AX (if equipped)
2-3
Platform Overload System, S-60,
S-65, S-60 TRAX and S-65 TRAX
(if equipped)
How to Calibrate the Platform
Overload System
Calibration of the platform overload system is
essential to safe machine operation. Continued use
of an improperly calibrated platform overload
system could result in the system failing to sense
an overloaded platform. The stability of the
machine is compromised and it could tip over.
Note: For S-60 HC models, Refer to Repair
Procedure, Platform Load Sense System, S-60
HC.
Note: Perform this procedure with the machine on
a firm, level surface.
1
Turn the key switch to platform control. Start
the engine and level the platform.
2
Determine the maximum platform capacity.
Refer to the machine serial plate.
3
Remove all weight, tools and accessories from
the platform.
Note: Failure to remove all weight, tools and
accessories from the platform will result in an
incorrect calibration.
4
Using a suitable lifting device, place a test
weight equal to the maximum platform
capacity at the center of the platform floor.
32
S-60 • S-65 • S-60 TRAX • S-65 TRAX • S-60 HC • S-60X • S-60XC Part No. 1268492
5
Move the platform up and down by hand, so it
bounces approximately 2.5 to 5 cm / 1 to
2 inches. Allow the platform to settle.
Result: The overload indicator lights are off
and the alarm does not sound. Proceed to
step 6.
Result: The overload indicator lights are
flashing at the platform and ground controls,
and the alarm is sounding. Slowly tighten the
load spring adjustment nut in a clockwise
direction in 10° increments until the overload
indicator light turns off, and the alarm does not
sound. Proceed to step 8.
Note: The platform will need to be moved up and
down and allowed to settle between each
adjustment.
Note: There may be a 2 second delay before the
platform overload indicator light and alarm
responds.
6
Move the platform up and down by hand, so it
bounces approximately 2.5 to 5 cm / 1 to
2 inches. Allow the platform to settle.
Result: The overload indicator lights are off at
the platform and ground controls, and the
alarm does not sound. Slowly loosen the load
spring adjustment nut in a counterclockwise
direction in 10° increments until the overload
indicator light flashes at both the platform and
ground controls, and the alarm sounds.
Proceed to step 7.
Result: The overload indicator lights are
flashing at the platform and ground controls,
and the alarm is sounding. Repeat this
procedure beginning with step 5.
September 2016