15 Activate and release the calibration toggle
switch inside the ground control box 1 time.
Result: The alarm should sound for 1 second
indicating the fifth calibration step was
accepted. The green LED on the operational
controller should be blinking fast and the red
LED should be blinking six times indicating
that step 6 of calibration is next.
16 Using a suitable lifting device, place an
additional test weight equal to 510 lbs /
231.3 kg on to the center of the platform floor.
The total weight in the platform must equal
1260 lbs / 571.5 kg.
17 Activate and release the calibration toggle
switch inside the ground control box 1 time.
Result: The alarm should sound for 1 second
indicating the sixth calibration step was
accepted. The engine may turn off and the
alarm may sound indicating an overloaded
platform.
18 At the ground controls, push in the red
Emergency Stop button to the off position,
then pull out the red Emergency Stop button to
the on position to reset the system.
19 Visually inspect the LEDs on the controllers.
Result: All LEDs on both controllers should be
off indicating the platform load sense system
is calibrated.
Part No. 1268492 S-60 • S-65 • S-60 TRAX • S-65 TRAX • S-60 HC • S-60X • S-60XC
Platform Components
20 At the ground controls, push in the red
Emergency Stop button to the off position.
21 Using a suitable lifting device, remove the test
weights from the platform.
22 Pull out the red Emergency Stop button to the
on position at the ground controls and visually
inspect the LEDs on the operational and
safety controllers.
Result: Both the green and red LEDs on both
controllers should be off indicating the system
is calibrated.
Note: If an LED is blinking on either controller, the
load sense system is not calibrated correctly or a
fault may exist. Refer to Fault Codes Section to
determine the system fault.
Platform Load Sens e - H ow to R es tor e System D efault Settings System, S- 60 HC
How to Restore the System
Default Settings
1
Turn the key switch to ground control and pull
out the red Emergency Stop button to the on
position.
Result: The alarm should sound a long tone.
2
Activate and hold the calibration toggle switch
for 5 seconds.
Result: The alarm should sound a tone for
1 second.
3
Push in the red Emergency Stop button to the
off position.
Service and Repair Manual