Genie S-65 Service And Repair Manual page 52

Hide thumbs Also See for S-65:
Table of Contents

Advertisement

September 2016
5
Activate and release the calibration toggle
switch 3 times within 2 seconds after the
alarm sounds to enter calibration mode.
Result: The alarm should sound for 1 second
indicating the first calibration step was
accepted. The green LED on the operational
controller should be blinking fast and the red
LED should be blinking twice indicating that
step 2 of calibration is next.
Result: The alarm did not sound and the green
LED on the operational controller is not
blinking fast. Repeat this procedure beginning
with step 1.
Note: Once calibration mode is entered and begun,
there is a 8 minute time limit between each
calibration step. If any one step passes the
8 minute time limit, the system will time out and the
calibration process will need to be repeated
beginning with step 1.
1 green LED (operational control module)
2 red LED (operational control module)
3 operational control module
4 safety control module
5 red LED (safety control module)
6 green LED (safety control module)
Part No. 1268492 S-60 • S-65 • S-60 TRAX • S-65 TRAX • S-60 HC • S-60X • S-60XC
Platform Components
6
Start the engine from the ground controls.
7
Raise the boom until the distance, when
measured between the centers of the pivot
pins shown, equals 108.75 inches / 276 cm ±
0.75 inch / 19 mm.
Crushing hazard. Keep clear of
all moving parts of the boom
while the boom is raising. Do not
attempt to measure between the
pivot pins while the boom is
moving.
Service and Repair Manual