Platform Load Sense System,
S-60 HC
How to Calibrate the Platform
Load Sense System
Proper calibration of the load sense system is
essential to safe machine operation. Continued use
of an improperly calibrated load sense system
could result in the system failing to sense an
overloaded platform. The stability of the machine is
compromised and it could tip over.
Note: For S-60, S-65, S-60 TRAX and S-65 TRAX
models, Refer to Repair Procedure, Platform
Overload System, S-60, S-65, S-60 TRAX and
S-65 TRAX (if equipped).
Note: Perform this procedure with the boom fully
retracted and in the stowed position and with the
machine on a firm, level surface.
Note: The platform overload system will not allow
partial calibration and must be completed in its
entirety.
1
At the ground controls, turn the key switch to
the off position and push in the red Emergency
Stop button to the off position. Pull out the red
Emergency Stop button to the on position at
the platform controls.
34
S-60 • S-65 • S-60 TRAX • S-65 TRAX • S-60 HC • S-60X • S-60XC Part No. 1268492
2
Remove all weight, tools and equipment from
the platform.
Tip-over hazard. Failure to
remove all weight, options,
accessories and/or tools from
the platform or subtracting the
weight of those items from the
test weights, will result in the
platform load sense system not
calibrating correctly. This will
allow too much weight to be
added to the platform which will
result in the machine tipping
over.
3
Open the ground control box and locate the
calibration toggle switch near the relays.
Note: If either the operational and/or safety
controller has been replaced or if the software has
been updated, restore the system to the default
settings and then continue to step 4. Refer to
Repair Procedure, How to Restore the Default
Settings. Otherwise, continue to step 4 to enter
calibration mode.
4
Turn the key switch to ground control and pull
out the red Emergency Stop button to the on
position.
Result: The alarm sound for approximately
2 seconds.
September 2016