Genie S-65 Service And Repair Manual page 50

Hide thumbs Also See for S-65:
Table of Contents

Advertisement

September 2016
Note: The platform will need to be moved up and
down and allowed to settle between each
adjustment.
Note: There may be a 2 second delay before the
platform overload indicator lights and alarm
responds.
7
Move the platform up and down by hand, so it
bounces approximately 2.5 to 5 cm / 1 to
2 inches. Allow the platform to settle.
Result: The overload indicator lights are off
and the alarm does not sound. Proceed to
step 8.
Result: The overload indicator lights are
flashing at the platform and ground controls,
and the alarm is sounding. Repeat this
procedure beginning with step 5.
Note: There may be a 2 second delay before the
platform overload indicator light and alarm
responds.
8
Add an additional 10 lb / 4.5 kg test weight to
the platform.
Result: The overload indicator light is flashing
at both the ground and platform controls, and
the alarm is sounding. Proceed to step 9.
Result: The overload indicator light is off at
both the ground and platform controls, and the
alarm does not sound. Remove the additional
10 lb / 4.5 kg test weight. Repeat this
procedure beginning with step 6.
Note: There may be a 2 second delay before the
platform overload indicator light and alarm
responds.
Part No. 1268492 S-60 • S-65 • S-60 TRAX • S-65 TRAX • S-60 HC • S-60X • S-60XC
Platform Components
9
Test all machine functions from the platform
controls.
Result: All platform control functions should
not operate.
10 Turn the key switch to ground control.
11 Test all machine functions from the ground
controls.
Result: All ground control functions should not
operate.
12 Using a suitable lifting device, lift the test
weight off the platform floor.
Result: The platform overload indicator light
should be off at both the ground and platform
controls and the alarm should not sound.
Note: There may be a 2 second delay before the
overload indicator lights and alarm turn off.
13 Test all machine functions from the ground
controls.
Result: All ground control functions should
operate normally.
14 Turn the key switch to platform control.
15 Test all machine functions from the platform
controls.
Result: All platform control functions should
operate normally.
Service and Repair Manual