Genie S-65 Service And Repair Manual page 131

Hide thumbs Also See for S-65:
Table of Contents

Advertisement

Service and Repair Manual
Deutz D 2.9 L4 Engine Fault Codes
SPN = Suspect Parameter Number
FMI = Failure Mode Identifier
KWP = Keyword Protocol
SPN FMI
KWP
Description
175
2
738
Sensor oil temperature;
plausibility error
175
2
739
Sensor oil temperature;
plausibility error oil temperature
too high
175
3
743
Sensor error oil temperature;
signal range check high
175
4
744
Sensor error oil temperature;
signal range check low
190
0
389
Engine speed above warning
threshold (FOC-Level 1)
190
2
421
Offset angle between crank- and
camshaft sensor is too large
190
8
419
Sensor camshaft speed;
disturbed signal
190
8
422
Sensor crankshaft speed;
disturbed signal
190
11
390
Engine speed above warning
threshold (FOC-Level 2)
190
12
420
Sensor camshaft speed; no
signal
190
12
423
Sensor crankshaft speed; no
signal
190
14
391
Engine speed above warning
threshold (Overrun Mode)
190
14
1222
Camshaft- and Crankshaft speed
sensor signal not available on
CAN
411
0
791
Physical range check high for
differential pressure Venturiunit
(EGR)
411
1
792
Physical range check low for
differential pressure Venturiunit
(EGR)
411
3
795
Sensor error differential pressure
Venturiunit (EGR); signal range
check high
411
4
381
Physical range check low for
EGR differential pressure
411
4
796
Sensor error differential pressure
Venturiunit (EGR); signal range
check low
114
S-60 • S-65 • S-60 TRAX • S-65 TRAX • S-60 HC • S-60X • S-60XC Part No. 1268492
SPN FMI
KWP
Description
412
3
1007
Sensor error EGR cooler
downstream temperature; signal
range check high
412
4
1008
Sensor error EGR cooler
downstream temperature; signal
range check low
520
9
306
Timeout Error of
CAN-Receive-Frame TSC1TR;
Setpoint
597
2
49
Break lever mainswitch and
break lever redundancy switch
status not plausible
624
3
971
SVS lamp; short circuit to batt.
624
4
972
SVS lamp; short circuit to grd.
624
5
969
SVS lamp; open load
624
12
970
SVS lamp; powerstage over
temperature
630
12
376
Access error EEPROM memory
(delete)
630
12
377
Access error EEPROM memory
(read)
630
12
378
Access error EEPROM memory
(write)
639
14
84
CAN-Bus 0 "BusOff-Status"
651
3
580
Injector 1 (in firing order); short
circuit
651
4
586
High side to low side short circuit
in the injector 1 (in firing order)
651
5
568
Injector 1 (in firing order);
interruption of electric connection
652
3
581
Injector 2 (in firing order); short
circuit
652
4
587
High side to low side short circuit
in the injector 2 (in firing order)
652
5
569
Injector 2 (in firing order);
interruption of electric connection
653
3
582
Injector 3 (in firing order); short
circuit
653
4
588
High side to low side short circuit
in the injector 3 (in firing order)
653
5
570
Injector 3 (in firing order);
interruption of electric connection
September 2016