Service and Repair Manual
Boom Components
4-7 Primary Boom Angl e Sens or, S-60X and S- 60XC
4-7
Primary Boom Angle Sensor,
S-60X and S-60XC
The primary boom angle sensor works in
conjunction with the boom extend limit switches
when restricted maximum platform load is selected
from the platform controls maintaining the working
envelope. The primary boom angle sensor is
located on the ground control side long link arm.
How to Replace the Primary
Boom Angle Sensor
1
From the ground controls raise the primary
boom until it is fully elevated.
2
Push in the red Emergency Stop button to the
off position and turn the key switch to the off
position.
3
Locate the primary boom angle sensor
mounted on the ground control side long link
arm.
4
Cut and discard the two button cable ties
securing the angle sensor harness to the
gusset plate.
5
Locate and disconnect the angle sensor
harness connector.
6
Remove the angle sensor retaining fasteners
and set aside. Remove the angle sensor.
56
S-60 • S-65 • S-60 TRAX • S-65 TRAX • S-60 HC • S-60X • S-60XC Part No. 1268492
7
Install the angle sensor onto the hex key.
Refer to the illustration for proper alignment.
1 button cable ties
2 start orientation
3 finish orientation
4 gusset plate
8
Install the angle sensor retaining fastners. Do
not tighten at this time.
9
Route the angle sensor harness through the
gusset plate and secure using two button
cable ties.
10 Securely connect the angle sensor harness to
the main harness.
September 2016