Genie S-65 Service And Repair Manual page 132

Hide thumbs Also See for S-65:
Table of Contents

Advertisement

September 2016
SPN = Suspect Parameter Number
FMI = Failure Mode Identifier
KWP = Keyword Protocol
SPN FMI
KWP
Description
654
3
583
Injector 4 (in firing order); short
circuit
654
4
589
High side to low side short circuit
in the injector 4 (in firing order)
654
5
571
Injector 4 (in firing order);
interruption of electric connection
676
11
543
Cold start aid relay error.
676
11
544
Cold start aid relay open load
677
3
956
Starter relay high side; short
circuit to battery
677
3
960
Starter relay low side; short
circuit to battery
677
4
957
Starter relay high side; short
circuit to ground
677
4
961
Starter relay low side; short
circuit to ground
677
5
958
Starter relay; no load error
677
12
959
Starter relay; powerstage over
temperature
703
3
426
Engine running lamp; short circuit
to battery
703
4
427
Engine running lamp; short circuit
to ground
703
5
424
Engine running lamp; open load
703
12
425
Engine running lamp;
powerstage over temperature
729
5
545
Cold start aid relay open load
729
12
547
Cold start aid relay; over
temperature error
898
9
305
Timeout Error of
CAN-Receive-Frame TSC1TE;
Setpoint
1079 13
946
Sensor supply voltage monitor
1 error (ECU)
1080 13
947
Sensor supply voltage monitor
2 error (ECU)
Part No. 1268492 S-60 • S-65 • S-60 TRAX • S-65 TRAX • S-60 HC • S-60X • S-60XC
Deutz D 2.9 L4 Engine Fault Codes
SPN FMI
1109 2
1136 0
1136 1
1136 3
1136 4
1176 3
1176 4
1180 0
1180 0
1180 0
1180 1
1180 1
1180 1
1180 3
1180 11
1188 2
Service and Repair Manual
KWP
Description
121
Engine shut off demand ignored
1398
Physikal range check high for
ECU temperature
1399
Physikal range check low for
ECU temperature
1400
Sensor error ECU temperature;
signal range check high
1401
Sensor error ECU temperature;
signal range check low
849
Sensor error pressure sensor
upstream turbine; signal range
check high
850
Sensor error pressure sensor
downstream turbine; signal range
check high
1193
Physical range check high for
exhaust gas temperature
upstream turbine
1460
Turbocharger Wastegate CAN
feedback; warning threshold
exceeded
1462
Exhaust gas temperature
upstream turbine; warning
threshold exceeded
1194
Physical range check low for
exhaust gas temperature
upstream turbine
1461
Turbocharger Wastegate CAN
feedback; shut off threshold
exceeded
1463
Exhaust gas temperature
upstream turbine; shut off
threshold exceeded
1067
Sensor error exhaust gas
temperature upstream turbine;
signal range check high
1066
Sensor exhaust gas temperature
upstream turbine; plausibility
error
1414
Wastegate; status message from
ECU missing
115

Advertisement

Table of Contents
loading

This manual is also suitable for:

S-60xS-60 traxS-65 traxS-60xcS-60

Table of Contents