Error Source 31, Boom Angle Operational Sensor (C123PBS)
Error Type
ID Name
5
Sensor tolerance fault
11 Output short high
12 Value too high
15 Value too low
16 Output short low
17 Not calibrated
18 Just calibrated
Part No. 1268492 S-60 • S-65 • S-60 TRAX • S-65 TRAX • S-60 HC • S-60X • S-60XC
Condition
Power relays disengaged.
Power relays disengaged.
Boom angle sensor wiring
open or shorted to voltage.
Power relays disengaged.
Boom angle sensor wiring
open or shorted to voltage OR
sensor is out of operating
range
Power relays disengaged.
Boom angle sensor wiring
open OR shorted to ground
OR sensor is out of operating
range.
Power relays disengaged.
Boom angle sensor wiring
open OR shorted to ground.
Boom range of motion is
limited.
Used to clear diagnostic
codes.
Service and Repair Manual
Fault Codes
Solution
Repair wiring and/or connections OR
replace boom angle sensor and calibrate
overload system.
Repair wiring and/or connections OR
replace boom angle sensor and calibrate
overload system.
Repair wiring and/or connections OR
adjust or replace boom angle sensor and
calibrate overload system.
Repair wiring and/or connections OR
adjust or replace boom angle sensor and
calibrate overload system.
Repair wiring and/or connections OR
replace boom angle sensor and calibrate
overload system.
Calibrate the platform load sense system.
Self-clearing.