September 2016
Error Source
Error Type
ID
Name
ID
45
Platform Level
21
Switch
46
Primary
21
Extend/Retract
Switch
51
Drive Joystick
11
12
15
16
17
53
Drive Flow Valve
12
(EDC)
15
17
Part No. 1268492 S-60 • S-65 • S-60 TRAX • S-65 TRAX • S-60 HC • S-60X • S-60XC
Condition
Name
Fault
Platform level frozen at neutral
Fault
Platform Ext/Ret frozen at neutral Power up controller with
Value at 5V
Limited speed and direction.
Frozen at zero and neutral. Alarm
sounds indicating a fault.
Value too high
Value too low
Value at 0V
Not calibrated
Value too high
Limited speed and direction.
Frozen at zero and neutral. ALarm
sounds indicating a fault.
Value too low
Not calibrated
Normal function except threshold
for one or both directions is zero.
Control System Fault Codes
Service and Repair Manual
Solution
Power up controller with
problem corrected
problem corrected
Cycle power off, then on after
problem has been corrected.
Calibrate joystick.
Cycle power off, then on after
problem has been corrected.
Calibrate valve threshold.