Error Source 41, Load Cell Operational (C175LDS)
Error Type
ID Name
5
Sensor tolerance fault
11 Output short high
12 Value too high
15 Value too low
16 Output short low
17 Not calibrated
18 Just calibrated
Part No. 1268492 S-60 • S-65 • S-60 TRAX • S-65 TRAX • S-60 HC • S-60X • S-60XC
Condition
Power relays disengaged.
Power relays disengaged.
Load cell wiring open OR
shorted to voltage. Platform
may be overloaded.
Power relays disengaged.
Load cell wiring open OR
shorted to voltage. Platform
may be reverse loaded.
Power relays disengaged.
Load cell wiring open OR
shorted to ground.
Power relays disengaged.
Load cell wiring open OR
shorted to ground.
Boom range of motion is
limited.
Used to clear diagnostic
codes.
Service and Repair Manual
Fault Codes
Solution
Repair wiring and/or connections OR
replace platform load cell and calibrate
overload system.
Repair wiring and/or connections OR
replace platform load cell and calibrate
overload system.
Repair wiring and/or connections OR
replace platform load cell OR remove
excess weight from platform.
Repair wiring and/or connections OR
replace platform load cell and calibrate
overload system. Check for binding of the
overload component linkage and be sure
platform is NOT on the ground OR
supported from underneath.
Repair wiring and/or connections OR
replace platform load cell and calibrate
overload system.
Calibrate the platform load sense system.
Self-clearing.
137