25.11 Alert Priority, Alert State - Furuno FMD-3200 Operator's Manual

Electronic chart display and information system
Hide thumbs Also See for FMD-3200:
Table of Contents

Advertisement

25. ALERT MANAGEMENT SYSTEM (option)
IEC 62288 Ed.2 buzzer pattern
This buzzer complies with INS regulations. There are two types of buzzer patterns,
Emergency/Alarm and Warning.
Emergency/Alarm: The buzzer sounds three times in 7-second intervals.
Emergency/Alarm generated.
Buzzer ON
Buzzer OFF
0.5 seconds
IEC 62288 Ed.2 mode, emergency/alarm priority buzzer
Warning: The buzzer sounds twice and is then muted.
Warning generated.
Buzzer ON
Buzzer OFF
0.5 seconds

25.11 Alert Priority, Alert State

There are seven priority numbers according to the priority of the alert and alert state.
25-10
7 seconds
Buzzer muted
IEC 62288 Ed.2 mode, warning priority buzzer
Priority No.
Priority of Alert
High
1
Emergency, Alarm
2
Warning
3
Emergency, Alarm
4
Warning
5
Emergency, Alarm
6
Warning
7
Caution
Low
Time
Buzzer muted
Time
Alert state
Not acknowledged, Not rectified
Not acknowledged, Not rectified
Not acknowledged, Rectified
Not acknowledged, Rectified
Acknowledged, Not rectified
Acknowledged, Not rectified
Not rectified
ACK
ACK

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fmd-3200-bbFmd-3300

Table of Contents