ACTIVE ALERT window
The [ACTIVE ALERT] window shows the status of all active alerts. A maximum of 20
alerts is shown per page. When there are more than 20 active alerts, a new page is
created to hold the new alerts. You can move between pages with the arrow buttons.
The background color of an unacknowledged emergency or alarm flashes red and an
unacknowledged warning flashes yellow-orange. The text of an acknowledged emer-
gency or alarm is red and the text of an acknowledged warning is yellow-orange. The
text of a caution is yellow. Category B alerts can be acknowledged by clicking the alert
or the [ACK] button. The buzzer for category A alerts can be temporarily stopped by
clicking the alert; but, acknowledgement must be done from the equipment that gen-
erated the alert.
Transferring
See the next page for a description of the items in the list.
No.
Item name
1
[ACK] button
2
[Silence] button
3
Decision Support box
4
Alert Icon description
button
25. ALERT MANAGEMENT SYSTEM (option)
SILENT
Acknowledges all active alerts.
Temporarily silences the buzzer.
Right click the box to show the reason for the alert and remedy.
Provides a description of the alert icons.
Emergency/Alarm
icons (Red)
Warning icon
(Yellow-orange)
Caution icon (yellow)
Aggregate icon
Alarm icon (Red)
Warning icon
(Yellow-orange)
Description
E
E
25-17