Furuno FMD-3200 Operator's Manual page 462

Electronic chart display and information system
Hide thumbs Also See for FMD-3200:
Table of Contents

Advertisement

APPENDIX 5 ALERT LIST
ALF
ALR
No.
Inst.*
No.
30001
6
015
30001
7
016
30001
8
017
30001
9
011
30001
10
024
30001
11
012
30001
12
025
AP-42
Priority/
Alert name
Category
Sub Monitor Fan2
Caution/B
Rotation Speed
Lowering
Sub Monitor Fan3
Rotation Speed
Lowering
Sub Monitor Fan4
Rotation Speed
Lowering
Main Monitor
RS485 Communi-
cation Timeout
Sub Monitor
RS485 Communi-
cation Timeout
Main Monitor No
Signal
Sub Monitor No
Signal
Meaning
For MU-231: Con-
If the error fre-
nected to COM2
quently occurs,
(Sub Monitor).
contact FURUNO
Fan2 rotation speed
and inform fre-
is below threshold.
quency of occur-
rence.
For MU-231: Con-
If the error fre-
nected to COM2
quently occurs,
(Sub Monitor).
contact FURUNO
Fan3 rotation speed
and inform fre-
is below threshold.
quency of occur-
rence.
For MU-190: Con-
If the error fre-
nected to COM2
quently occurs,
(Sub Monitor).
contact FURUNO
Fan4 rotation speed
and inform fre-
is below threshold.
quency of occur-
rence.
For MU-190/231:
Check the connec-
Connected to
tion of brightness
COM1. There has
control cable.
been no communi-
cation from proces-
sor unit through
RS485 for 180 sec-
onds. (No commu-
nication implies in
completed sen-
tence or checksum
error.)
For MU-190/231:
Check the connec-
Connected to
tion of brightness
COM2. There has
control cable.
been no communi-
cation from proces-
sor unit through
RS485 for 180 sec-
onds. (No commu-
nication implies
incomplete sen-
tence or checksum
error.)
For MU-190/231:
Check the connec-
Connected to
tion of video cable.
COM1. There has
been no signal con-
tinuously for 60 sec-
onds.
For MU-190/231:
Check the connec-
Connected to
tion of video cable.
COM2. There has
been no signal con-
tinuously for 60 sec-
onds.
Remedy