Item No.
U106
Supplement
While this maintenance item is being executed, copying from an original is available in interrupt
copying mode (which is activated by pressing the system menu key).
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
U107
Setting the transfer cleaning voltage
Description
Sets the cleaning control voltage for transfer belt unit.
Purpose
Change settings if an offset has occurred due to the failure of cleaning the transfer belt.
Method
1. Press the start key.
2. Select the item to be set.
Display
Belt(A)
Belt(B)
3. Select the item to be set.
4. Change the value using the +/- or numeric keys.l
Display
Full
Half
3/4
B/W
5. Press the start key. The value is set.
Supplement
While this maintenance item is being executed, copying from an original is available in interrupt
copying mode (which is activated by pressing the system menu key).
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Description
Transfer belt cleaning voltage (printing)
Transfer belt cleaning voltage (paper interval)
Description
Full speed
0 to 255
Half speed
0 to 255
0 to 255
Black/white mode
0 to 255
1-3-78
Description
Setting
range
30 ppm 35 ppm 45 ppm 55 ppm
86
74
86
74
86
74
86
74
2LK/2LN/2LM/2LC
Initial setting
86
97
86
97
86
97
86
97