Kyocera TASKalfa 3050ci Service Manual page 274

Hide thumbs Also See for TASKalfa 3050ci:
Table of Contents

Advertisement

Code
Contents
1950
Transfer belt unit EEPROM
error
No response is issued from
the device in reading/writing
for 5 ms or more and this
problem is repeated 5 times
successively.
Mismatch of reading data from
2 locations occurs 8 times
successively.
Mismatch between writing
data and reading data occurs
8 times successively.
2101
Developer motor K error
[30 ppm/35 ppm model]
After developer motor K is
driven, the ready signal does
not turn to L within 2 s.
After developer motor K is sta-
bilized, the ready signal is at
the H level for 1 s continu-
ously.
[45 ppm/55 ppm model]
After developer motor K is
driven, the ready signal can-
not be detected for 5 s.
2102
Developer motor MCY error
After developer motor MCY is
driven, the ready signal can-
not be detected for 5 s.
Causes
Defective connec-
Reinsert the connector. Also check for conti-
tor cable or poor
nuity within the connector cable. If none,
contact in the con-
replace the cable.
nector.
Transfer belt unit and engine PWB (YC3)
Defective transfer
Replace the transfer belt unit and check for
belt unit.
correct operation (see 1-5-41).
Defective connec-
Reinsert the connector. Also check for conti-
tor cable or poor
nuity within the connector cable. If none,
contact in the con-
replace the cable.
nector.
Developer motor K and motor control PWB
(YC7)
Motor control PWB (YC3) and engine PWB
(YC9)
Defective drive
Check if the gears rotate smoothly. If not,
transmission sys-
grease the bushes and gears. Check for
tem of motor.
broken gears and replace if any.
Defective devel-
Replace the developer motor K.
oper motor K.
Defective engine
Replace the engine PWB and check for cor-
PWB.
rect operation (see page 1-5-54).
Defective connec-
Reinsert the connector. Also check for conti-
tor cable or poor
nuity within the connector cable. If none,
contact in the con-
replace the cable.
nector.
Developer motor MCY and motor control
PWB (YC7)
Motor control PWB (YC3) and engine PWB
(YC9)
Defective drive
Check if the gears rotate smoothly. If not,
transmission sys-
grease the bushes and gears. Check for
tem of motor.
broken gears and replace if any.
Defective devel-
Replace the developer motor MCY.
oper motor MCY.
Defective engine
Replace the engine PWB and check for cor-
PWB.
rect operation (see page 1-5-54).
1-4-34
2LK/2LN/2LM/2LC
Check procedures/
corrective measures

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Taskalfa 3550ciTaskalfa 4550ciTaskalfa 5550ci

Table of Contents