17. Remove two connectors.
18. Remove six screws.
19. Unhook the hook of the PWB spacer
and then fuser IH PWB.
20. Check or replace the fuser IH PWB and
refit all the removed parts.
Screws
Screws
Connector
PWB spacer
Figure 1-5-112
1-5-69
2LK/2LN/2LM/2LC
Screws
Connector
Fuser IH PWB