Technical Data; Technical Data Control Unit Udk20 - Roland R1000 Series Manual

Double sheet detector with integrated fieldbus interface
Hide thumbs Also See for R1000 Series:
Table of Contents

Advertisement

B0048191 / Rev. 1.5

2 Technical data

2.1

Technical data control unit UDK20

Operating voltage:
Power consumption:
Switch on current:
External fuse:
Weight:
Ambient temperature:
Wall mount enclosure:
Protection category:
Dimensions without screw fittings:
Dimensions with screw fittings:
Front panel enclosure:
Protection category:
Dimensions:
Additional characteristics:
255 parameter sets memory
Programming via pushbuttons or fieldbus
3 potential free optocoupler inputs 24 VDC with joint common
Specification:
 min. switching voltage HIGH:
 max. switching voltage HIGH:
 min. switching voltage LOW:
 max. switching voltage LOW:
5 potential free optocoupler outputs with positive external supply
Specification:
 max. switching voltage:
 max. switching current:
 max. switching power:
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Double Sheet Detector R1000 series UDK20
with integrated fieldbus interface
Attention
In case of inductive load a coil protection diode should be used.
Otherwise the signal output could be destroyed by the excess voltage
generated by switching the inductive load off.
Manual
24 VDC, +6 V / -2 V
60 W (operation: <60 W, in idle: <10 W)
10 Amps for 1 ms
5 Amps medium time lag
approx. 1.5 kg (3.30 lbs)
0 - 50 °C (30 - 122° F)
IP65
approx. 225 x 240 x 80 mm (L x W x H)
approx. 8.85 x 9.45 x 3.15 inch (L x W x H)
approx. 225 x 360 x 80 mm (L x W x H)
approx. 8.85 x 14.2 x 3.15 inch (L x W x H)
IP40 (inside)
IP65 (front cover)
approx. 240 × 240 × 120 mm (L x W x H)
approx. 9.45 × 9.45 × 4.7 inch (L x W x H)
20 VDC
30 VDC
0 VDC
8 VDC
50 VDC
100 mA (internal current limitation)
2.4 W (only resistor load)
Technical data
9

Advertisement

Table of Contents
loading

This manual is also suitable for:

R1000 udk20

Table of Contents