Mitsubishi FX3U-4AD User Manual page 33

Fx3g series fx3u series fx3uc series
Hide thumbs Also See for FX3U-4AD:
Table of Contents

Advertisement

FX
/FX
/FX
PLC User's Manual - Analog Control Edition
3G
3U
3UC
Common Items
Type
Voltage/current input/output mixture
FX
-5A
*1
2N
FX
-3A
*1, *4
0N
Temperature sensor input
FX
-8AD
*1
2N
FX
-4AD-TC
*1
2N
FX
-4AD-PT
*1
2N
FX
-2LC
*1
2N
*1. To connect this block to the FX
*2. Refer to the instruction manual of the respective product.
*3. The offset and gain of the FX
indication mode or analog value mV (or
*4. The FX
-3A cannot be connected to the FX
0N
No. of
Range
channels
Voltage:
-10V to +10V DC
Input
4ch
Current:
-20mA to +20mA DC
Voltage:
-10V to +10V DC
Output
1ch
Current:
0mA to 20mA DC
Voltage:
0V to 10V DC
Input
2ch
Current:
4mA to 20mA DC
Voltage:
0V to 10V DC
Output
1ch
Current:
4mA to 20mA DC
Type K:
-100°C to +1200°C
Type J:
-100°C to +600°C
8ch
Type T:
-100°C to +350°C
Type K:
-100°C to +1200°C
4ch
Type J:
-100°C to +600°C
Pt100:
4ch
-100°C to +600°C
Example:
Type K:
-100°C to +1300°C
2ch
Pt100:
-200°C to +600°C
Series PLC, either the FX
3UC
-5A cannot be adjusted for channels using the analog value direct
2N
Resolution
0.32mV
(with sign, 16 bits)
Combined use of voltage and
1.25µA
current is possible.
(with sign, 15 bits)
The offset/gain can be
adjusted.
5mV
The scaling function is
(with sign, 12 bits)
incorporated.
20µA
(10bits)
40mV
(8bits)
64µA
The input format is common to 2
(8bits)
channels.
The offset/gain can be adjusted.
40mV
(Common to 2 input channels)
(8bits)
64µA
(8bits)
Combined use of voltage,
0.1°C
current, and thermocouple is
possible.
0.1°C
Compatible with thermocouple
types K, J, and T.
The unit can be switched between
"Centigrade" and "Fahrenheit."
0.1°C
The sampling function is
incorporated.
Compatible with thermocouple
0.4°C
types K and J.
The unit can be switched between
0.3°C
"Centigrade" and "Fahrenheit."
Compatible with the platinum
resistance thermometer sensor
0.2°C to 0.3°C
(Pt100 or JPt100).
The unit can be switched between
"Centigrade" and "Fahrenheit."
Compatible with thermocouple
types K, J, R, S, E, T, B, N, PL II,
WRe5-26, U, and L.
Compatible with the platinum
resistance thermometer sensor
(Pt100, JPt100).
0.1°C or 1°C
The unit can be switched between
(Depends on the
"Centigrade" and "Fahrenheit."
sensor input range.)
The temperature adjustment
function (PID operation, etc.) is
incorporated.
The peak disconnection
detection function is
incorporated.
(A CT sensor is needed.)
-CNV-IF or FX
2NC
µ
A) specification mode.
Series PLC.
3G
2 Description of Analog Products
2.2 List of Analog Product Models
Refer-
Function
ence
*2
*3
*2
*2
*2
*2
*2
-1PS-5V is required.
3UC
A-11
A
B
C
D
E
F
G
H
I
J