Mitsubishi FX3U-4AD User Manual page 107

Fx3g series fx3u series fx3uc series
Hide thumbs Also See for FX3U-4AD:
Table of Contents

Advertisement

FX
/FX
/FX
PLC User's Manual - Analog Control Edition
3G
3U
3UC
FX
-4AD/FX
-4AD (4-channel Analog Input)
3U
3UC
5.4.4
BFM #10 to #13: Channel data
Use these buffer memories to store the A/D converted digital values.
The channel data (BFM #10 to #13 for channels 1 to 4) and the data update timing will depend on the set
averaging time (BFM #2 to #5 for channels 1 to 4) or the digital filter setting condition (BFM #6 to #9 for
channels 1 to 4) as shown in the following table.
Averaging
time
(BFM #2 to #5)
0 (The digital filter
0 or less
will not be used.)
0 (The digital filter
will not be used.)
1
1 to 1600
(The digital filter
will be used.)
2 to 400
0 (The digital filter
will not be used.)
401 to 4095
4096 or more
*1.
"500µs" represents the A/D conversion time.
However, if one of the channels uses the digital filter function, the A/D conversion time will be 5 ms for
all the channels.
→ For a detailed description of the averaging time, refer to Subsection 5.4.2.
→ For a detailed description of digital filter functions, refer to Subsection 5.4.3.
Digital filter
function
Channel data type
(BFM #6 to #9)
Immediate data
"0" will be set, and the
averaging time setting error
(b10 of BFM #29) will occur.
Immediate data
Immediate data
The digital filter function will
be used.
Average data
Average data
Average data
"4096" will be set, and the
averaging time setting error
(b10 of BFM #29) will occur.
Numeric data type: Decimal (K)
Channel data (BFM #10 to #13) update timing
Each time the A/D conversion is performed, the
data will be updated.
The update timing will be as follows:
Update time = 500µs
selected channels
Each time the A/D conversion is performed, the
data will be updated.
The update timing will be as follows:
Update time = 5ms × Number of selected
channels
Each time the A/D conversion is performed, the
data will be updated.
The update timing will be as follows:
Update time = 500µs
selected channels
Each time the A/D conversion is performed for
the set averaging time, the data will be updated.
The update timing will be as follows:
Update time = 500µs
selected channels × Averaging time
5 Buffer Memory (BFM)
5.4 Buffer Memory Details
Update timing
*1
× Number of
*1
× Number of
*1
× Number of
B-31
A
B
C
D
E
F
G
H
I
J

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents