Mitsubishi FX3U-4AD User Manual page 256

Fx3g series fx3u series fx3uc series
Hide thumbs Also See for FX3U-4AD:
Table of Contents

Advertisement

FX
/FX
/FX
PLC User's Manual - Analog Control Edition
3G
3U
3UC
FX
-4DA (4-channel Analog Output)
3U
2. Example of sequence program
• For FX
, FX
3U
Initial pulse
M8002
RUN monitor
M8000
T0
X000
X001
X002
RUN monitor
M8000
D202.2
D202.3
D200.0
*1.
The output mode setting, setting of corrective function by load characteristics and status automatic
transfer function setting are retained in the EEPROM of FX
sequence program is deleted, the previously set functions will still be valid.
*2.
After setting the output mode, set the data writing time (waiting time) to 5 seconds or more for each
setting. After the output mode is specified, and the same output mode is used, it is not necessary to
set the output mode and the waiting time (T0 K50).
E-58
Series PLCs
3UC
FNC 12
H2200
MOV
P
T0
FNC 12
H1122
MOV
P
FNC 16
K-3200 U0\G41
FMOV
P
FNC 16
K6400
U0\G43
FMOV
P
FNC 16
K28800 U0\G45
FMOV
P
FNC 16
K25600 U0\G47
FMOV
P
FNC 12
H0011
MOV
P
FNC 16
K5000
U0\G51
FMOV
P
FNC 12
H0007
MOV
P
FNC 12
H0003
MOV
P
FNC 12
K0
MOV
P
FNC 12
K0
MOV
P
FNC 15
D10
U0\G1
BMOV
FNC 12
D201
MOV
Y010
Y011
U0\G0
Output modes of channels 1 to 4 will be specified
K50
*2
Upper/lower limit function setting
U0\G38
Setting of lower limit values for channels 1 and 2
K2
Setting of lower limit values for channels 3 and 4
K2
Setting of upper limit values for channels 1 and 2
K2
Setting of upper limit values for channels 3 and 4
K2
Corrective function setting by load resistance
U0\G50
Setting of load resistance values for channels 1 and 2
K2
Status automatic transfer function setting
U0\G60
(The initial setting of destination data registers is used,
and the sequence program for this function is omitted.)
U0\G40
Clearance of upper/lower limit function status data
Clearance of error status data
U0\G29
Clearance of disconnection detection status data
U0\G28
K4
Transfer of data that will be output from channels 1 to 4
Output of upper/lower limit error status of channels to
K2Y000
Y000 to Y007
Disconnection detected in channels 3 and 4
Output to Y010
Error detected Output to Y011
8 Examples of Practical Programs
8.2 Example of Program using Useful Functions
*1
*1
-4DA. For this reason, even if the
3U
*1
*1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents