Mitsubishi FX3U-4AD User Manual page 217

Fx3g series fx3u series fx3uc series
Hide thumbs Also See for FX3U-4AD:
Table of Contents

Advertisement

FX
/FX
/FX
PLC User's Manual - Analog Control Edition
3G
3U
3UC
FX
-4DA (4-channel Analog Output)
3U
BFM number
Data to be output from channel 1 upon PLC stop
*1
#32
(Valid only if BFM #5 = H
Data to be output from channel 2 upon PLC stop
*1
#33
(Valid only if BFM #5 = H
Data to be output from channel 3 upon PLC stop
*1
#34
(Valid only if BFM #5 = H 2
Data to be output from channel 4 upon PLC stop
*1
#35
(Valid only if BFM #5 = H2
#36, #37
Not used
#38
Upper/lower limit function setting
#39
Upper/lower limit function status
#40
Clear of upper/lower limit function status
#41
Channel-1 lower limit of upper/lower limit function
#42
Channel-2 lower limit of upper/lower limit function
#43
Channel-3 lower limit of upper/lower limit function
#44
Channel-4 lower limit of upper/lower limit function
#45
Channel-1 upper limit of upper/lower limit function
#46
Channel-2 upper limit of upper/lower limit function
#47
Channel-3 upper limit of upper/lower limit function
#48
Channel-4 upper limit of upper/lower limit function
#49
Not used
Corrective function setting by load resistance
*1
#50
(Valid only in voltage output mode)
*1
Load resistance value for channel 1 (Unit: Ω)
#51
*1
Load resistance value for channel 2 (Unit: Ω)
#52
Load resistance value for channel 3 (Unit: Ω)
*1
#53
*1
Load resistance value for channel 4 (Unit: Ω)
#54
#55 to #59
Not used
*1
Status automatic transfer function setting
#60
Error status data (BFM #29) automatic transfer-
*1
to data register specification (Valid if b0 of BFM
#61
#60 is set to ON)
Upper/lower limit function status data (BFM #39)
*1
automatic transfer-to data register specification
#62
(Valid if b1 of BFM #60 is set to ON)
Disconnection detection status data (BFM #28)
*1
automatic transfer-to data register specification
#63
(Valid if b2 of BFM #60 is set to ON)
#64 to #79
Not used
*1.
If power failure occurs, the EEPROM will retain the data.
*2.
Specify the use of the upper/lower limit function for each channel setting one of hex code 0 to 2 in
each digit.
*3.
Use b0 to b1.
*4.
Specify the use of the corrective function by load resistance for each channel setting a hex code 0 or
1 in each digit.
*5.
Use b0 to b2.
Description
2)
2 )
)
)
Setting range
Initial value
Depending on the
K0
mode used
Depending on the
K0
mode used
Depending on the
K0
mode used
Depending on the
K0
mode used
-
-
*2
H0000
-
H0000
*3
H0000
K-32640
K-32640
Depending on the
mode used
K-32640
K-32640
K32640
K32640
Depending on the
mode used
K32640
K32640
-
-
*4
H0000
K1000 to K30000
K30000
K1000 to K30000
K30000
K1000 to K30000
K30000
K1000 to K30000
K30000
-
-
*5
K0
K200
K0 to 7999 (BFM
#61, #62 and #63
K201
must have different
values.)
K202
-
-
5 Buffer Memory (BFM)
5.3 Buffer Memory List (BFM)
Data type
Reference
Decimal
Decimal
Subsection
5.4.12
Decimal
Decimal
-
-
Hexadeci-
Subsection
mal
5.4.13
Hexadeci-
Subsection
mal
5.4.14
Hexadeci-
Subsection
mal
5.4.15
Decimal
Decimal
Subsection
5.4.16
Decimal
Decimal
Decimal
Decimal
Subsection
5.4.16
Decimal
Decimal
-
-
Hexadeci-
Subsection
mal
5.4.17
Decimal
Decimal
Subsection
5.4.17
Decimal
Decimal
-
-
Subsection
Decimal
5.4.18
Subsection
Decimal
5.4.19
Subsection
Decimal
5.4.20
Subsection
Decimal
5.4.21
-
-
E-19
A
B
C
D
E
F
G
H
I
J

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents