Mitsubishi FX3U-4AD User Manual page 240

Fx3g series fx3u series fx3uc series
Hide thumbs Also See for FX3U-4AD:
Table of Contents

Advertisement

FX
/FX
/FX
PLC User's Manual - Analog Control Edition
3G
3U
3UC
FX
-4DA (4-channel Analog Output)
3U
4. Example of data table
The following table shows an example of data table containing two patterns prepared in and after D5000.
Patterns 1 and 2 are in the output mode 1.
Data
register
D5000
D5001
D5002
D5003
D5004
D5005
D5006
D5007
D5008
D5009
D5010
D5011
D5012
D5013
D5014
D5015
D5016
D5017
D5018
D5019
D5020
D5021
D5022
D5023
D5024
D5025
E-42
Set value
K2
Number of patterns
K3
Number of points in pattern 1
K0
Setting of condition after output at final point in pattern 1
K3000
Data to be output at point 1 in pattern 1
K18
Output update time at point 1 in pattern 1
Output update time unit at point 1 in pattern 1
H0021
Point-to-point interpolation method
K8000
Data to be output at point 2 in pattern 1
K26
Output update time at point 2 in pattern 1
Output update time unit at point 2 in pattern 1
H0011
Point-to-point interpolation method
K5000
Data to be output at point 3 in pattern 1
K5
Output update time at point 3 in pattern 1
Output update time unit at point 3 in pattern 1
H0011
Point-to-point interpolation method
K4
Number of points in pattern 2
K1
Setting of condition after output at final point in pattern 2
K2000
Data to be output at point 1 in pattern 2
K6
Output update time at point 1 in pattern 2
Output update time unit at point 1 in pattern 2
H0022
Point-to-point interpolation method
K10000
Data to be output at point 2 in pattern 2
K15
Output update time at point 2 in pattern 2
Output update time unit at point 2 in pattern 2
H0002
Point-to-point interpolation method
K500
Data to be output at point 3 in pattern 2
K45
Output update time at point 3 in pattern 2
Output update time unit at point 3 in pattern 2
H0021
Point-to-point interpolation method
K4000
Data to be output at point 4 in pattern 2
K9
Output update time at point 4 in pattern 2
Output update time unit at point 4 in pattern 2
H0012
Point-to-point interpolation method
6 Table Output Function
Description
6.2 Preparation of data table
2 patterns
3 points
Holding
of
value
output at final point
3V
1800 ms
100 ms
S-shaped interpolation
8V
2600 ms
100 ms
Linear interpolation
5V
500 ms
100 ms
Linear interpolation
4 points
Output of offset value
2V
6s
1s
S-shaped interpolation
10V
15s
1s
No interpolation
0.5V
4500 ms
100 ms
S-shaped interpolation
4V
9s
1s
Linear interpolation

Hide quick links: