3. Push the feeding foot (2) down slightly by hand.
4. Tighten the screw (3).
5. Turn the handwheel and check if the presser foot (3) and the feeding
13.3 Setting the adjusting frame
Fig. 51: Setting the adjusting frame
(1) - Sewing foot stroke adjusting wheel
(2) - Slot
To set the adjusting frame:
1. Turn the handwheel to the 0° position.
2. Place a 3 mm hex key under the feeding foot.
3. Loosen the screws (3).
4. Position the adjusting wheel for the sewing foot stroke (1) to level 3.
5. Manually lower the feeding foot down onto the hex key.
6. Center the stroke lever (4) in the slot (2).
7. Tighten the screws (3).
Important
8. Ensure that the stroke lever (4) does not shift.
66
foot (2) are at the same height.
If this is not the case, adjust the feeding foot (2) until the movement is
correct.
①
②
③
Sewing feet
(3) - Screws
(4) - Stroke lever
Service Instructions 1767 - 00.0 - 12/2016
④