Set Target - Kyocera TASKalfa 1800 Service Manual

Hide thumbs Also See for TASKalfa 1800:
Table of Contents

Advertisement

U425

Set Target

Description
Enters the lab values that is indicated on the back of the chart (P/N: 7505000005) used for adjust-
ment.
Purpose
Performs data input in order to correct for differences in originals during automatic adjustment.
Method
1. Press the start key.
2. Select the item to be set.
Display
White
Black
Gray1
Gray2
Gray3
C
M
Y
R
G
B
Adjust Original
Adjust OriginalDP
3. Select the item to be set.
Display
L
a
b
4. Enters the value that is indicated on the face of the chart using change keys * or numeric keys.
* : Zoom/Paper selection key (Basic model), Right/Left arrow key (Advanced model)
5. Press the start key. The value is set.
Setting the white patch for the original for adjustment
Setting the black patch for the original for adjustment
Setting the Gray1 patch for the original for adjustment
Setting the Gray2 patch for the original for adjustment
Setting the Gray3 patch for the original for adjustment
Setting the cyan patch for the original for adjustment
Setting the magenta patch for the original for adjustment
Setting the yellow patch for the original for adjustment
Setting the red patch for the original for adjustment
Setting the green patch for the original for adjustment
Setting the blue patch for the original for adjustment
Setting the main and auxiliary scanning directions
Setting each value of DP detection position.
Description
Setting the L value
Setting the a value
Setting the b value
1-3-78
2NC/2NF/2NG/2NN/3P7/3P8/3P9-5
Description
Setting range
-200.0 to 200.0
-200.0 to 200.0
0.0 to 100.0